

10201/2/1 Honeywell Fail-safe Digital Output Module
Non-redundant IO configurations
Non-redundant IO configurations can be used in systems with a non-redundant Controller as well as in systems with redundant Controller. Fully non-redundant systems are typically used for safety applications where redundancy is part of the process.
In a Safety Manager setup with a redundant Controller, and (partly) nonredundant IO, both Control Processors alternately assume responsibility for the non-redundant IO interfaces. This ensures both Control Processors can always access the IO interfaces correctly.
Safety Manager configurations with a redundant Controller and non-redundant IO interfaces are typically used for safety critical applications with increased demands for system availability, for example because of redundancy in plant equipment.
The combination of redundant and non-redundant IO interfaces is extremely powerful. Process safeguarding functions requiring optimal availability are controlled through the redundant IO interfaces, and less demanding safety functions through the non-redundant IO interfaces.
Available interfaces are:
In the Safety Manager Guides an approved basic Fire and Gas Safety application is included. This application provides a Fire and Gas Safety Solution that can easily be integrated into Honeywell’s Experion™ PKS,10105/2/1Honeywell’s TotalPlant Solution (TPS) system or into Honeywell’s PlantScape system. The basic application can be developed and adjusted easily to design a project specific Fire and Gas Safety Solution.
The integrated layer of the F&G solution within Experion, TPS or PlantScape contains the integrated alarm listing and safety historian functionality that records all detected alarms, all actions initiated by the F&G Safety system and all actions executed by this system or connected integrated sub-systems.10105/2/1This layer also shows the actual situation of the F&G application by using overall plant displays and various detailed area displays that contain locations and actual status of all connected F&G field detectors.
Our Advantage Products
|
Allen Bradley |
ABB | Honeywell |
| 1746-NI16I | 07ZE61R302 GJV3074321R302 | 8U-PAOHA1 |
| 1746-NI4 | NTCF02 | 51153818-101 |
| 1746-NI8 | DASA110 3ASC25H705/7 | 8C-TAIXA1 51307127-175 |
| 1746-NIO4I | SAFT188IOC SAFT188IOC | 51153818-201 |
| 1746-NIO4V | DSQC668 3HAC029157-001 | 8U-PDILA1 |
| 1746-NO4I | CBHX165C 5R 414 | 900RTR-H001 |
| 1746-NO4V | BRC400 P-HC-BRC-40000000 | 51155506-101 |
| 1746-NO8I | DSQC663 3HAC029818-001 | 51400855-100 |
| 1746-NO8V | 3HNP01759-1 | MC-TD0Y23 |
| 1746-NR4 | DSTC120 57520001-A | 900RTC-H010 |
| 1746-NR8 | DSCA125A 57520001-CY | 51304489-100 |
Our products are all genuine imported goods in stock, which can be tested, worry-free after-sales service, and quality guaranteed.
We have tens of thousands of models and tens of thousands of stocks in stock, welcome to consult!
Global direct procurement guarantee
All products are purchased directly from overseas original manufacturers or authorized channels, 100% guaranteed genuine quality, sufficient spot inventory, and comprehensive model coverage
Quality Commitment
Each product has been tested by our technicians, providing 12-month long warranty, worry-free after-sales
Flexible procurement plan
- Bulk order enjoys Friendship discount (2 pieces or more can be applied)
- Long-term cooperative customers can apply for priority supply
Full service support
7×24 hours technical consultation, from selection guidance to installation and commissioning to provide full life cycle service (paid)
Why do so many customers choose us?
On the basis of the same quality, we provide:
- More competitive price system
- Faster logistics response
- More complete technical support (free product technical documentation)
Your trust is the driving force for our continuous progress, submit your requirements immediately to get exclusive quotes
